Ul 1709 standard download

The protection of structural steel in hydrocarbon fires. Reprinted from the online certifications directory with permission from underwriters laboratories inc. Mastic coating spray applied in one or more coats to the thickness shown in the table below. Ul announced january 30 that ul certification customers in north america will have free online access to all ul safety standards beginning immediately. About underwriters laboratories ul ul is an independent, privately held product safety consulting, testing and certification company. Having covered millions of square meters over a period of 10 years, chartek 1709 can be used with confidence for pool fires up to four hours, jet fires and vessel protection. Boronfree chartek 2218 is certified for up to four hours pool fire protection in addition to being jet fire tested.

The method is already a mandatory requirement within ansiul 1709. The standard was originally developed to provide fire testing requirements suitable for materials exposed to the rapidly rising high temperatures typically observed in high intensity, hydrocarbonbased fires. Standard for rapid rise fire tests of protection materials for structural steel proposals dated 122206 replaced standard. The test method covers a fullscale fire exposure, intended to evaluate the thermal resistance of protective material appli. This article is about fireproofing ul 1709 fire protection installation of fireproof ul 2196 and focusing to the engineers, technicians and supervisors.

It is designed to protect against hydrocarbon fire scenarios for up to 4 hours as defined in the ansiul 1709 standard. Over the last two decades, the ansiul 1709, the standard for rapid rise fire tests of protection materials for structural steel, for structural steel fire protection has grown in importance across the worldwide petrochemical industry. Ul 1709 ul standard for safety rapid rise fire tests of. Ul1709 standards in refineries and chemical plants unitherm. Fire resistance ratings ansiul 1709 see general information for fire resistance ratings ansiul 1709 design no. Is iec 60331 test sufficient for fire resistive cables in. Ul 1709 ul standard for safety rapid rise fire tests of protection materials for structural steel, third edition including revision of 2007 professional documents reference title api publ 2218 fireproofing practices in petroleum and petrochemical processing plant, second edition, 1999. Find the most uptodate version of ul 1769 at engineering360. Department of transportation dot or the corresponding specifications and regulations of transport canada tc. Founded in 1894, it is one of the major nationally recognized testing laboratories in the usa, approved by the. Boronfree chartek 2218 is certified for up to four hours pool fire.

Using patented technology, it offers our lowest certified thickness for longer duration fires. Since september 1983, ul has tested and listed fireproofing materials on the basis of ul 1709. This standard describes a test method for measuring the resistance of protective materials to rapidtemperaturerise fires. Only products which bear uls mark are considered as classified, listed, or recognized. Our breadth, established objectivity and proven history mean we are a symbol of trust, enabling us to help provide peace of mind to all. Pdfacrobat reader or word version doc document file size. Jotachar 1709 mesh free epoxy passive fire protection. Buy ul standards online ul standards catalog comm 2000. This product is ul classified for protection of both interior and exterior steel substrates for up to three hours. That uses cellulosic temperatures and is not appropriate. Ul 1709 ul standard for safety rapid rise fire tests of protection materials for structural steel. All ansi approved standards scc approved standards. Ansicanul standard for software cybersecurity for networkconnectable products, part 1. Jotachar 1709 is the mesh free, next generation epoxy passive fire protection pfp material for pool fires in the hydrocarbon processing industry.

Jotachar 1709 mesh free epoxy passive fire protection jotun. Structural steel fire protection testing and certification. Do not forget to subscribe our you tube channel also. Some ul standards are ibr incorporated by reference into the us code of federal regulations. About ul 1709 ul 1709, rapid rise fire test of protection materials for structural steel, was first published in 1989. Ul provides free access to library of safety standards. Jan 05, 2017 the ul 1709 test provides the closest representation of a fire that a petrochemical facility could experience. These requirements cover shutoff valves, with or without relief valve, that are for use on cylinders that comply with the specifications and charging and maintenance regulations of the u. Ansi ul 2431, the standard for durability of fireresistive coatings and materials, is used to evaluate the protective coating against the longterm effects of environmental exposure, often a critical factor in the performance of materials as well as vibration and impact. It is designed to protect against hydrocarbon fire scenarios for up to 4 hours as defined in the ansi ul 1709 standard. Ul 1703 standard for flatplate photovoltaic modules and.

About the ul 1709 standard the most common fire standard for equipment fire protection in. The protection of structural steel in hydrocarbon fires ul. In fact, the american petroleum institute, in document api 2218 fireproofing practices in petroleum and petrochemical processing plants recommends that critical circuit cables survive for 15 to 30 minutes under ul 1709 conditions. The temperature rise of the ul1709 is more severe than the european hydrocarbon fire hc. Underwriters laboratories ul is the mostly used usbody to certify solar panels for the us market and issues the prominent ul 1703 certification. The keywords are fireproofing ul 1709 fire protection installation of fireproof ul 2196. Chartek 2218 is our latest epoxy pfp system for installations requiring certification to the ul 1709 standard. Approval of structural steel protection materials for.

The timetemperature curve in ul 1709 represents the conditions associated with burning pools of hydrocarbon fuels. The ul 1709 test provides the closest representation of a fire that a petrochemical facility could experience. Steel above ground tanks for flammable and combustible liquids 49 cfr 1910. The ul 1709 timetemperature curve is also shown in figure 1. When choosing ul, you are opting for the proven performance of an independent and accredited testing partner. Find the most uptodate version of ul 1709 at engineering360. Ul 1769 ul standard for safety cylinder valves engineering360. The entire library of uls standards and outlines of investigations will be available through a dedicated web site at ul recognizes the time constraints manufacturers face when bringing. Ul1709 standards in refineries and chemical plants. The representative tank is placed in a 2000 f rapid rise furnace that meets the requirements of ul 1709, standard for rapid rise fire tests of. Xr618 april 23, 2001 ratings 1, 112, 2, 212, 3, 312, and 4 hr 1. In todays post well discuss the most common standard for equipment fire protection, ul1709. Xr618 december 28, 2012 ratings 12, 1, 112, 2, 212, 3, 312, and 4 hr.

Structural steel fire protection testing and certification ul. Ul 1709 standard for rapid rise fire tests of protection materials. Changes to the california building code cbc and the california residential code crc require all pv systems permitted after january 1, 2015 be tested, listed. The companies below have provided the association with proper documentation confirming they have passed the required testing for ul 1703 3rd edition may 2014 fire classification.

Products often have ul 1709 test evidence but must have gost approval also which results in lower protection thicknesses and lower. The standard, in addition to characterizing the material for fire endurance, also requires tests to determine the weatherability of the material. Lloyds register certification pool fire in accordance with standard ul 1709 lloyds register certification jet fire in accordance with standard oti 95634 and iso 228991 lloyds register certification resistance to blast generated overpressure of 2. You will find lot of documents related to this article. Ul 1709 pdf free 11 download 95ec0d2f82 standard test methods reference chart. Fire resistant cable for the petrochemical industry. Part of our ul 1709 product offer, boronfree chartek 1709 provides long term corrosion and fire protection in a single system. The method is already a mandatory requirement within ansi ul 1709. Steel above ground tanks for flammable and combustible liquids author. The intent of the ul 1709 test standard is to evaluate the thermal.

The test method covers a fullscale fire exposure, intended to evaluate the thermal resistance of protective material applied to structural members and the ability of the protective material to withstand the fire exposure. Ul 2085 has the following performance test requirements. Aug 01, 2011 when planning updates for gas refineries, chemical plants or any other facility with hazardous materials, engineers often require that equipment meet specific fire codes and standards. Ul provides free access to library of safety standards rp news wires, noria corporation underwriters laboratories inc. Ul 1709 standard for rapid rise fire tests of protection. By authority of the united states of america legally binding document by the authority vested by part 5 of the united states code 552a and part 1 of the code of regulations 51 the attached document has been duly. Cable to maintain circuit integrity during fire test. Ul 1703 fire classification new ul 1703 fire classification requirements took effect on jan 1, 2015. When planning updates for gas refineries, chemical plants or any other facility with hazardous materials, engineers often require that equipment meet specific fire codes and standards. That means it satisfies uls 1709 standard for rapid rise fire tests of protection materials for structural steel, the most common industry standard required by insurance providers. The ul 1709 standard test method is used to assess the fire resistance performance, in minutes, for nonload bearing protected steel column structures exposed to a rapid time temperature curve as shown in fig. Benefit from our highly experienced team of experts and long history of expertise in plastics testing.

Standard for flatplate photovoltaic modules and panels. Ul 1703 standard for flatplate photovoltaic modules and panels fire test section 31. A wide variety of ul 1709 options are available to you, there are 24 suppliers who sells ul 1709 on, mainly located in asia. The standard, in addition to characterizing the material for fire endurance, also requires tests to determine the. Rapidrise fire test fireresistance designs for protecting structural members subject to petrochemical exposure fires are investigated according to ansiul 1709, rapid rise fire tests of protection materials for structural steel, and are covered under fireresistance ratings ansiul 1709 bybu. Changes to the california building code cbc and the california residential code crc require all pv systems permitted after january 1, 2015 be tested, listed, and identified with a fire classification per ul 1703.

What is the ul 1709 standard, and where is it applicable. The paper then discusses the requirements of ul 1709 and. Uls best practice guide for passive fire protection for structural steelwork. Ul 1709 standard the ul 1709 standard rapid rise fire test of protection materials for structural steel is one of the oldest and most frequently used furnace test standards for the oil and gas industry. Ul offers allinclusive services and competitive turnaround times. The entire library of ul s standards and outlines of investigations will be available through a dedicated web site at ul recognizes the time constraints manufacturers face when bringing. No specific hydrocarbon standard specified by the russian codes. Standard for rapid rise fire tests of protection materials for structural steel. Readonly copies of those standards are available to the public at the ul website the following ul standards are available in paper copy in the noble library on the tempe campus. Materials currently on the market are often tested to the gost standard only gost r 53295. A ul1709 fire is a rapid rise fire that reaches 2000f within the first 5 minutes of the fire exposure test. Ul standard for safety rapid rise fire tests of protection. Ul 1709 fire test standard rapid rise fire tests of protection.

1077 5 4 836 1024 1503 1398 1406 948 1445 31 852 200 835 1191 791 205 20 1434 733 426 1231 269 13 354 50 628 1185 659 875 104 1231 917 790 841 885 696 501 753 845